Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Anesthesiology ; (12): 406-409, 2023.
Article in Chinese | WPRIM | ID: wpr-994204

ABSTRACT

Objective:To evaluate the gastric emptying in the patients with cholelithiasis and in the patients following cholecystectomy by ultrasonography.Methods:Thirty patients with cholelithiasis, 30 post-cholecystectomy patients and 30 healthy volunteers, of either sex, aged 18-64 yr, with body mass index of 18-30 kg/m 2, of American Society of Anesthesiologists Physical Status classification Ⅰor Ⅱ, were selected and divided into cholelithiasis group (group CH), post-cholecystectomy group (group PC) and healthy volunteer group (group HV). The indigestion scores of the enrolled subjects in the past 3 months were assessed; the subjects took a semi-solid test meal (300 kcal) in the fasting state, and the cross-sectional area (CSA) of the gastric sinus was measured using ultrasound at fasting (T 0) and 5, 15, 30, 45, 60, 90 and 120 min after the test meal was taken (T 1-7). The gastric emptying fraction at T 5, 6 was calculated. The gastric half-emptying time and remaining area of the gastric sinus at T 7 were also calculated. Results:Compared with group HV, dyspepsia scores were significantly increased within the past 3 months ( P<0.05), the CSA of the gastric sinus was increased at T 3-7, the gastric emptying fraction was decreased at T 5-6, the gastric half-emptying time was prolonged, and the remaining area of the gastric sinus was increased at T 7 in group CH and group PC ( P<0.05). Compared with group CH, the CSA of the gastric sinus was significantly increased at T 4-7, the gastric emptying fraction was decreased at T 5, 6, the gastric half-emptying time was prolonged, and the remaining area of the gastric sinus was increased at T 7 in group PC ( P<0.05). Conclusions:Gastric emptying time is longer in the patients with cholelithiasis and in the patients following cholecystectomy than in healthy subjects and is further prolonged after cholecystectomy in the patients.

2.
Chinese Journal of Ultrasonography ; (12): 869-871, 2008.
Article in Chinese | WPRIM | ID: wpr-398071

ABSTRACT

Objective To investigate the value of the diagnosis of contrast-enhanced ultrasound(CEUS) in renal tumors. Methods Nineteen patients with hyperechoic renal tumors detected by CEUS underwent resection for suspected renal malignant and benign tumors. The characterization of hyperechoic renal tumors on CEUS was evaluated. Results Histopathologic results of resected lesions showed benign tumors in 11 patients with angiomyolipoma and malignancy in 8 patients with clear cell carcinoma. Six patients with angiomyolipoma showed rapid wash in contrast enhancement and slow wash out on all tumor and focal tumor (6/11). One patient with angiomyolipoma was observed in rapid wash in and wash out (1/11). Four patients with angiomyolipoma showed rapid wash in and negative contrast enhancement after rapid wash out(negative contrast enhancement compared to renal cortex,4/11). Five patients with clear cell carcinoma showed rapid wash in and wash out (5/8). Two patients with clear cell carcinoma showed rapid wash in and delayed wash out (2/8). One patient with showed no enhancement on CEUS (1/8). The pseudocapsule could be seen at 5 patients with clear cell carcinoma. Wash in enhancement and wash out on clear cell carcinoma were significant in comparison to these of angiomyolipoma (P<0.05). Wash in enhancement,delayed wash out and negative contrast enhancement were no significant between clear cell carcinoma and angiomyolipoma (P>0.05). Conclusions CEUS is useful for discriminating between benign and malignant renal tumor.

3.
Journal of Medical Postgraduates ; (12)2004.
Article in Chinese | WPRIM | ID: wpr-588448

ABSTRACT

With the advance of modern imaging technologies,many examinations,especially for ultrasound,have been used for the screening examination of breast cancers.This article reviewed the character and prospect of ultrasound for breast cancers.

4.
Journal of Medical Postgraduates ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-591714

ABSTRACT

Objective:To evaluate the characteristics of contrast-enhanced ultrasonography in renal VX2 tumors.Methods: VX2 tumors were transplanted into 12 rabbit kidneys and observations were made by contrast-enhanced ultrasonography 7,14 and 21 days after the transplantation respectively.Results: The best intervention time was 2-3 weeks after the tumor transplantation,while nicrosis was apt to occur after 3 weeks.The visibility of the renal tumors was significantly increased from 57.1%(12/21) to 100%(21/21).Contrast-enhanced ultrasonography showed defect and delineation of VX2 tumors. Conclusion: Contrast-enhanced ultrasonography can improve the peripheral and internal blood flows of the tumors promote the diagnosis of renal tumors.

SELECTION OF CITATIONS
SEARCH DETAIL